M14x1.5 tap drill size and thread dimensions
M14x1.5 has a major diameter of 14.000 mm and a pitch of 1.5 mm. Every other dimension below follows from those two numbers and the 60-degree thread form.
- Clearance hole
- 15.120
- Pitch diameter
- 13.0257
- Minor diameter of the nut thread
- 12.3762
- Minor diameter of the bolt thread
- 12.1597
- Tensile stress area
- 124.546 mm2
- Breaking load at that tensile strength
- 99 636
- The old "diameter minus pitch" drill
- 12.500
- Engagement that rule actually gives
- 92.4 %
- Threads engaged over that length
- 14.00
- Equivalent threads per inch
- 16.933
Show the working
- Thread engagement = 75
- Clearance hole allowance = 8
- Length of engagement = 21
- Material tensile strength = 800
- major = 14 = 14
- p = 1.5 = 1.5
- h = 1.5 * 0.8660254037844386 = 1.299 04
- Tap drill = 14 - 75/100 * 1.082532 * 1.5 = 12.7822
- The old "diameter minus pitch" drill = 14 - 1.5 = 12.5
- Engagement that rule actually gives = 100 / 1.082532 = 92.376
- Pitch diameter = 14 - 0.649519 * 1.5 = 13.0257
- Minor diameter of the nut thread = 14 - 1.082532 * 1.5 = 12.3762
- Minor diameter of the bolt thread = 14 - 1.226869 * 1.5 = 12.1597
- Tensile stress area = pi/4 * (14 - 0.938194 * 1.5)^2 = 124.546
- Clearance hole = 14 * (1 + 8/100) = 15.12
- Breaking load at that tensile strength = 124.546 * 800 = 99 636.4
- shear_area = pi * 12.3762 * 21 * (0.5 + 0.57735 * (13.0257 - 12.3762)/1.5) = 612.376
- Threads engaged over that length = 1.5 > 0 ? 21 / 1.5 : 0 = 14
- Equivalent threads per inch = 1.5 > 0 ? 25.4 / 1.5 : 0 = 16.9333
Values are shown to six significant figures here; the arithmetic itself runs on exact fractions and is only rounded where a number is printed.
Scenarios & local history
Compare a saved scenario
Recent calculations
The formula
- tap drill = D - (engagement / 100) x 1.082532 x P
- pitch diameter = D - 0.649519 P
- internal minor diameter = D - 1.082532 P
- tensile stress area = (pi/4)(D - 0.938194 P)^2
The familiar "drill equals diameter minus pitch" rule actually produces about 92% thread engagement, not 75%. Past roughly 75% the extra holding power is negligible and the tapping torque rises sharply, which is why 75% or even 65% is the shop standard.
The tensile stress area formula is the ISO 898-1 definition, based on the mean of the pitch and minor diameters.
Cut a clearance hole rather than a close fit unless the joint is dowelled: thread clearance is what lets parts line up.
M14x1.5 at common engagements
| Engagement | Tap drill (mm) | Tap drill (in) |
|---|---|---|
| 65% | 12.945 | 0.5096 |
| 70% | 12.863 | 0.5064 |
| 75% | 12.782 | 0.5032 |
| 80% | 12.701 | 0.5000 |
| 85% | 12.620 | 0.4968 |
| 90% | 12.539 | 0.4936 |
Pick the nearest drill above the figure, never below it.
Frequently asked
What drill size do I need for M14x1.5?
12.78 mm (0.5032 in) for 75% thread engagement. The traditional rule gives 12.50 mm, which is a tighter and harder-tapping hole.
What is the pitch of M14x1.5?
1.5 mm.
Where the numbers come from
- Thread geometry follows the ISO 68-1 basic profile shared by ISO metric and Unified inch threads; the stress-area definition is from ISO 898-1.