M10x1.25 tap drill size and thread dimensions

M10x1.25 has a major diameter of 10.000 mm and a pitch of 1.25 mm. Every other dimension below follows from those two numbers and the 60-degree thread form.

%
%
MPa
Tap drill
8.985mm
≈ Rounded M10x1.25 tap drill
Clearance hole
10.800
Pitch diameter
9.1881
Minor diameter of the nut thread
8.6468
Minor diameter of the bolt thread
8.4664
Tensile stress area
61.199 mm2
Breaking load at that tensile strength
48 959
The old "diameter minus pitch" drill
8.750
Engagement that rule actually gives
92.4 %
Threads engaged over that length
12.00
Equivalent threads per inch
20.320
Show the working
  1. Thread engagement = 75
  2. Clearance hole allowance = 8
  3. Length of engagement = 15
  4. Material tensile strength = 800
  5. major = 10 = 10
  6. p = 1.25 = 1.25
  7. h = 1.25 * 0.8660254037844386 = 1.082 53
  8. Tap drill = 10 - 75/100 * 1.082532 * 1.25 = 8.985 13
  9. The old "diameter minus pitch" drill = 10 - 1.25 = 8.75
  10. Engagement that rule actually gives = 100 / 1.082532 = 92.376
  11. Pitch diameter = 10 - 0.649519 * 1.25 = 9.1881
  12. Minor diameter of the nut thread = 10 - 1.082532 * 1.25 = 8.646 84
  13. Minor diameter of the bolt thread = 10 - 1.226869 * 1.25 = 8.466 41
  14. Tensile stress area = pi/4 * (10 - 0.938194 * 1.25)^2 = 61.1986
  15. Clearance hole = 10 * (1 + 8/100) = 10.8
  16. Breaking load at that tensile strength = 61.1986 * 800 = 48 958.9
  17. shear_area = pi * 8.646 84 * 15 * (0.5 + 0.57735 * (9.1881 - 8.646 84)/1.25) = 305.604
  18. Threads engaged over that length = 1.25 > 0 ? 15 / 1.25 : 0 = 12
  19. Equivalent threads per inch = 1.25 > 0 ? 25.4 / 1.25 : 0 = 20.32

Values are shown to six significant figures here; the arithmetic itself runs on exact fractions and is only rounded where a number is printed.

Scenarios & local history

Compare a saved scenario

Recent calculations

    The formula

    • tap drill = D - (engagement / 100) x 1.082532 x P
    • pitch diameter = D - 0.649519 P
    • internal minor diameter = D - 1.082532 P
    • tensile stress area = (pi/4)(D - 0.938194 P)^2

    The familiar "drill equals diameter minus pitch" rule actually produces about 92% thread engagement, not 75%. Past roughly 75% the extra holding power is negligible and the tapping torque rises sharply, which is why 75% or even 65% is the shop standard.

    The tensile stress area formula is the ISO 898-1 definition, based on the mean of the pitch and minor diameters.

    Cut a clearance hole rather than a close fit unless the joint is dowelled: thread clearance is what lets parts line up.

    M10x1.25 at common engagements

    Engagement Tap drill (mm) Tap drill (in)
    65% 9.1200.3591
    70% 9.0530.3564
    75% 8.9850.3537
    80% 8.9170.3511
    85% 8.8500.3484
    90% 8.7820.3458

    Pick the nearest drill above the figure, never below it.

    Frequently asked

    What drill size do I need for M10x1.25?

    8.99 mm (0.3537 in) for 75% thread engagement. The traditional rule gives 8.75 mm, which is a tighter and harder-tapping hole.

    What is the pitch of M10x1.25?

    1.25 mm.

    Where the numbers come from

    • Thread geometry follows the ISO 68-1 basic profile shared by ISO metric and Unified inch threads; the stress-area definition is from ISO 898-1.

    Related calculators

    Settings

    Theme

    System follows your operating system and changes with it.

    Text size
    High contrast

    Maximises text and border contrast and removes the grid background.

    Graph-paper background

    Round to
    Notation
    Thousands separators
    Decimal mark
    Nearest fraction

    Shows the result as the nearest tape-measure fraction, with the error it costs.


    Accessibility & interaction
    Reduce motion Stops interface animations even when the operating system does not.
    Underline links Keeps links visually distinct without relying on colour.
    Larger touch targets Makes buttons and form controls easier to tap.
    Shorter reading lines Limits article width for easier scanning.
    Monochrome display Removes colour as an information cue.
    Always-visible focus Makes the keyboard focus ring persistent and stronger.
    Verbose screen-reader results Announces the complete conversion equation.
    Sticky action bars Keeps converter and calculator actions within reach.
    Select values on focus Replaces a value immediately when you start typing.
    Left-handed mobile layout Moves key mobile actions toward the left thumb.

    Your data

    Settings, recent conversions and favourites live in this browser only. Nothing is sent anywhere.

    Offline library